Knowledge Center Catalog

Gas chromatographic analysis of amino acids as the N-Heptafluorobutyryl isobutyl esters (Record no. 67886)

MARC details
000 -LEADER
fixed length control field 02321nab a22003377a 4500
001 - CONTROL NUMBER
control field 67886
003 - CONTROL NUMBER IDENTIFIER
control field MX-TxCIM
005 - DATE AND TIME OF LATEST TRANSACTION
control field 20250407162948.0
008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION
fixed length control field 240909s1987 -uk|||p|op||| 00| 0 eng d
022 ## - INTERNATIONAL STANDARD SERIAL NUMBER
International Standard Serial Number 1060-3271
022 ## - INTERNATIONAL STANDARD SERIAL NUMBER
International Standard Serial Number 1944-7922 (Online)
024 8# - OTHER STANDARD IDENTIFIER
Standard number or code https://doi.org/10.1093/jaoac/70.1.151
040 ## - CATALOGING SOURCE
Original cataloging agency MX-TxCIM
041 ## - LANGUAGE CODE
Language code of text/sound track or separate title eng
100 1# - MAIN ENTRY--PERSONAL NAME
Personal name Mackenzie, S.L.
9 (RLIN) 36732
245 10 - TITLE STATEMENT
Title Gas chromatographic analysis of amino acids as the N-Heptafluorobutyryl isobutyl esters
260 ## - PUBLICATION, DISTRIBUTION, ETC. (IMPRINT)
Place of publication, distribution, etc. United Kingdom :
Name of publisher, distributor, etc. Oxford University Press,
Date of publication, distribution, etc. 1987.
500 ## - GENERAL NOTE
General note Peer review
520 ## - SUMMARY, ETC.
Summary, etc. The N-heptafluoroburyryl isobutyl derivatives of proteic amino acids are well resolved by gas chromatography and form the basis of a convenient, rapid assay. The derivatives are prepared by acid-catalyzed esterification at 120°C for 20 min in 3N HCl-isobutanol followed by acylation with heptafluorobutyric anhydride at 150°C for 10 min. The reaction sequence is performed without any transfers or extractions and thus is compatible with microscale analysis. A complete proteic amino acid profile can be completed in less than 20 min by using a packed column or less than 10 min by using a capillary column in combination with an elevated oven temperature program rate. Physiological sample matrixes, which frequently contain a complex mixture of components, and thus require maximum resolution, can be assayed in less than 1 h using a program rate of 4°C/min. A capillary column is recommended for this application. Capillary column chromatography, in combination with a nitrogen specific detector, is useful for identifying and assaying nonproteic amino acids in physiological sample matrixes. Frequently, a prior cleanup of the sample can be avoided.
546 ## - LANGUAGE NOTE
Language note Text in English
650 #7 - SUBJECT ADDED ENTRY--TOPICAL TERM
Topical term or geographic name as entry element Gas chromatography
Source of heading or term AGROVOC
9 (RLIN) 11840
650 #7 - SUBJECT ADDED ENTRY--TOPICAL TERM
Topical term or geographic name as entry element Analysis
Source of heading or term AGROVOC
9 (RLIN) 27824
650 #7 - SUBJECT ADDED ENTRY--TOPICAL TERM
Topical term or geographic name as entry element Amino acids
Source of heading or term AGROVOC
9 (RLIN) 4464
650 #7 - SUBJECT ADDED ENTRY--TOPICAL TERM
Topical term or geographic name as entry element Esters
Source of heading or term AGROVOC
9 (RLIN) 14127
650 #7 - SUBJECT ADDED ENTRY--TOPICAL TERM
Topical term or geographic name as entry element Lysine
Source of heading or term AGROVOC
9 (RLIN) 5257
650 #7 - SUBJECT ADDED ENTRY--TOPICAL TERM
Topical term or geographic name as entry element Aspartic acid
Source of heading or term AGROVOC
9 (RLIN) 36655
650 #7 - SUBJECT ADDED ENTRY--TOPICAL TERM
Topical term or geographic name as entry element Methionine
Source of heading or term AGROVOC
9 (RLIN) 25829
650 #7 - SUBJECT ADDED ENTRY--TOPICAL TERM
Topical term or geographic name as entry element Glutamic acid
Source of heading or term AGROVOC
9 (RLIN) 33892
773 0# - HOST ITEM ENTRY
Place, publisher, and date of publication United Kingdom : Oxford University Press, 1987.
Related parts v. 70, no. 1, p. 151–160
Title Journal of Association of Official Analytical Chemists
Record control number G446038
International Standard Serial Number 1060-3271
942 ## - ADDED ENTRY ELEMENTS (KOHA)
Source of classification or shelving scheme Dewey Decimal Classification
Koha item type Article
Suppress in OPAC No
Holdings
Date last seen Total Checkouts Price effective from Koha item type Lost status Source of classification or shelving scheme Damaged status Not for loan Collection code Withdrawn status Home library Current library Date acquired
09/09/2024   09/09/2024 Article Not Lost Dewey Decimal Classification     Reprints Collection   CIMMYT Knowledge Center: John Woolston Library CIMMYT Knowledge Center: John Woolston Library 09/09/2024

International Maize and Wheat Improvement Center (CIMMYT) © Copyright 2021.
Carretera México-Veracruz. Km. 45, El Batán, Texcoco, México, C.P. 56237.
If you have any question, please contact us at
CIMMYT-Knowledge-Center@cgiar.org